|
|
Electric
Boilers
“PRECISION”(USA) is a world-famous brand
for electric boilers. With over 50 years of R&D, production
and application, the products boast features of time-proving,
advanced technology, safe and reliable operation, long
service life, high heating efficiency, easy operation,
low failure and easy maintenance, etc.
◇ Compact size, small foot
print, e.g.
· Nanjin Xinhua Daily, hot water 690KW, boiler overall
size1422(L)X1016(W)X1600
(H)(mm)
· Shanghai No.1 Department Store, hot water 1170KW,
boiler overall size 1524(L)
X1220(W)X1905(H)(mm)
· Beijing Electric Power Science Research Institute,
hot water 2400KW, boiler overall
size 2490(L)X1727(W)X2260(H)(mm)
· Shanghai Jiangong Group Office Building, steam boiler
240KW, boiler overall size
1372(L)X915(W)X1296(H)(mm)
· Guizhou Shuangyang Airplane Manufacturing Plant, steam
boiler 1380KW, boiler
overall size 1626(L)X1575(W)X2058(H)(mm)
◇ Service life over 20 years
◇ Heating efficiency over
99%, supported by authoritative performance test report
◇ All PRECISION “Series II”
boilers and thermal storage systems are built to these
stringent standards:
· ASME Code,H、S、U symbols
· NEC/ NFPA 424-G
· UL Subject 834
· ASME Safety Code CSD-1
◇ “PRECISION” Heating Elements
· Individual immersion heating elements are 2 1/2” square
flanged for ease of
replacement. The elements are made of a highly corrosion-resistant
Incoloy-sheath
(332SS), with nickel-chromium resistance wire packed
in magnesium oxide power,
and configured in a U-tube design. Elements are limited
to 75 watts per square inch
power density to assure long life.
◇ All the electrical parts
and components are imported from USA, and made by world-
famous manufacturers like Honeywell.
◇ Cables are for high temperature
operation: cables for heating element wiring are good
for 200℃ (steam boiler) and 125℃ (hot water boiler),
cables for control wiring are
good for 105℃.
◇ Load control via PID pressure
/ temperature controller, step control with “first-on
first-
off” function for equalized heating element operation.
◇ Sufficient safety devices
· Two-stage high temperature / pressure limit (auto
reset and manual reset)
· Probe-type manual reset low water cutoff with test
circuit
· ASME safety valve(s)
· Cold startup protection
· Overcurrent protection, grounding protection, etc.
◇ Optional components include
PLC control w/color touch screen, BAS interface, multi-
boiler group control
◇ The local-assembled units
are made with domestic boiler tank as per “PRECISION”
drawings, heating elements and electrical components
supplied by PRECISION. |
|
|
 |
|